At FTIR Spectro, we know that selecting a hematology analyzer is a decision that can affect the work of a diagnostic lab on a daily basis. The instrument that is right for a laboratory should be able to handle the volume of blood tests performed, as well as the reporting requirements, space limitations, and the workflow of a routine test. FTIR Spectro, an analytical and hematology analyzer manufacturer, supplier, and exporter, offers laboratory instruments they would like to use based on a specific applications or technical requirements.
For all those involved in running a diagnostic center, hospital laboratory, or medical institution, choosing an appropriate hematology analyzer begins with knowing your laboratory’s requirements and knowing your laboratory’s needs in the future as testing requests increase.
Start With Your Laboratory’s Testing Needs
Be aware of the number of specimens you are processing per day, peak testing periods, and the type of report that your lab is going to require from you. The small diagnostic lab that processes complete blood counts (CBCs) may be operating under different circumstances than a hospital laboratory that is doing more work on a daily basis.
Consider what kind of samples you are expected to analyze, the manpower behind the device, and also the potential for growth in future analyses. Such data would help you in whittling down your choices prior to comparison of specifications.
3-part or 5-part differential, which is right for you?
In a 3-part hematology analyzer, white blood cell populations are normally classified into 3 groups: lymphocytes, MID or mixed cells, granulocytes. It could be appropriate for laboratories that have routine testing needs that can be satisfied by this degree.
Neutrophils, lymphocytes, monocytes, eosinophils, and basophils are generally distinguished as separate entities in a 5-part analyzer. This is useful in giving further details on the white blood cell differential and can be used in labs that need more comprehensive reports.
It is not necessarily based on the number of parameters advertised; the choice should be based on your testing menu and the clinical requirements. Blood smears may be indicated for some abnormalities, as may other tests, if applicable.
Read Carefully the Reportable Parameters
If you don’t need the measurements your laboratory requires, then a long parameter list is not helpful. Note the core CBC results, including white blood cell count (WBC), red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), platelet count (PLT), and the appropriate red cell indices: MCV, MCH, MCHC and RDW.
Ask the analyzer how he/she is going to report abnormal results. Where available, the use of flags, histograms and scattergrams can assist laboratory personnel in the identification of samples requiring further examination. Check the actual reporting function of the particular model before buying.
Think About Workflow, Sample Volume, and Throughput.
This does not mean that the hourly capacity to analyze the samples of the machine determines the daily capacity of the lab to analyze them because workflow is affected by several factors including start-up, quality control, reagent changes, maintenance, and repeated tests.
Check the sample aspiration volume, supported collection tubes, loading method, and options for barcode identification. If the instrument is for limited volume samples, make sure it is compatible with the type of sample required. Keep in mind its size, ventilation needs and operating conditions fit your space.
Determine the total cost of the purchase.
The first estimate is just a portion of the final cost. The cost of operating a hematology analyzer is affected by the continued usage of reagents, controls, calibrators, consumables, servicing and spare parts.
Inquire about the supplies covered, what supplies are required in addition, and the ease of obtaining supplies that are compatible. Also check storage conditions and consumption requirements. It is easier to compare equipment realistically and over the long-term when a clear understanding of running costs exists.
Quality Control and Support Must Be a Part of the Decision
Appropriate instrument verification, quality control, and performance monitoring procedures are essential for reliable testing. These topics are addressed by the guidelines set forth by the CLSI for automated hematology analyzers, which include user laboratory performance verification.
Before placing an order, make sure that installation, training, maintenance, warranty, and technical support are understood. A lab should also be aware of the reporting process for faults and where service and replacement parts can be sourced.
Find the Best Hematology Analyzers with FTIR Spectro
We at FTIR Spectro assist our customers in delving into analytical and laboratory instruments based on the applications and technical requirements. When considering a hematology analyzer, we recommend that laboratories verify the analyzer’s test capacity, operating requirements, documentation, and future supply prior to purchasing.
When you are discussing with a hematology analyzer manufacturer, supplier & exporter, remember to consider the instrument that will be able to do the work your laboratory actually requires, report, and resources, rather than just the length of the feature list.
Please reach out today and tell us your needs, and FTIR Spectro will provide you with additional product information and/or a quote.